Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/6391
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCAMPOS, Rômulo Augusto Lins de-
dc.creator.Latteshttp://lattes.cnpq.br/6038730639304761por
dc.contributor.advisor1BELIAN, Mônica Freire-
dc.contributor.advisor-co1NASCIMENTO, Valberes Bernardo do-
dc.contributor.advisor-co2LEMOS, Sherlan Guimarães-
dc.contributor.referee1PEREIRA, Claudete Fernandes-
dc.contributor.referee2LAVORANTE, André Fernando-
dc.contributor.referee3BATISTA, Élcio José-
dc.contributor.referee4FREITAS, Ana Paula de Sousa de-
dc.date.accessioned2017-02-16T13:10:45Z-
dc.date.issued2011-03-16-
dc.identifier.citationCAMPOS, Rômulo Augusto Lins de. Eletrodo íon-seletivo de pasta de carbono para determinação de cobre baseado em um novo Lariat-éter coroa. 2011. 49 f. Dissertação (Programa de Pós-Graduação em Química) - Universidade Federal Rural de Pernambuco, Recife.por
dc.identifier.urihttp://www.tede2.ufrpe.br:8080/tede2/handle/tede2/6391-
dc.description.resumoSensores potenciométricos são conhecidos por sua alta sensibilidade e seletividade. Tais sensores apresentam versatilidade, baixo custo e robustez, o que garante a esses sensores aplicabilidade em uma grande variedade de amostras químicas complexas. Os eletrodos íon-seletivos de membrana polimérica são os sensores potenciométricos mais conhecidos, por possuirem essas características. Contudo, os eletrodos modificados de pasta de carbono têm ganhado forte destaque devido ao avanço em seus estudos. Neste trabalho é proposto um eletrodo quimicamente modificado de pasta de carbono para determinação potenciométrica de cobre (II), utilizando um novo ionóforo lariat-éter coroa sintetizado a partir de precursor aminopropil trietoxisilano que é um agente sililante conhecido na literatura. Foram realizados estudos para avaliar a influência do pH sobre o potencial, o melhor tampão como eletrólito de suporte, além do planejamento experimental de misturas para se obter a melhor composição do EQMPC. O eletrodo proposto apresentou uma sensibilidade de 38,5mV/década de atividade com limite de detecção de 2,04 x 10-5 mol L-1, tendo como eletrólito de suporte um solução-tampão biftalato/HCl pH = 3,0 demonstrando ser promissor para aplicação na determinação de íons Cu(II). O eletrodo não apresentou sensibilidade analítica significativa aos íons Co(II), Ni(II) e Zn(II) sendo esses seus principais interferentes.por
dc.description.abstractPotentiometric sensors are known for their high sensitivity and selectivity. Such sensors have versatility, low cost and robustness, which ensures their applicability in a wide variety of complex chemical samples. The ion-selective electrodes for polymeric membrane are the best known potentiometric sensors, has by these traits. However, modified carbon paste electrodes have gained prominence due a great advance in their studies. This paper proposes an electrode chemically modified carbon paste for potentiometric determination of copper (II), using a new ionophore lariat-crown ether synthesized from precursor aminopropyl triethoxysilane is a silylating agent known in the literature. Studies were conducted to evaluate the influence of pH on the potential, the best buffer as supporting electrolyte, and the experimental design of mixtures to obtain the best composition of EQMPC. The proposed electrode showed a sensitivity of 38.5 mV/decade of activity with a detection limit of 2.04 x 10-5 mol L-1, and as a supporting electrolyte buffer biftalate/HCl pH = 3.0 proving to be promising for application in the determination of Cu(II). The electrode showed no significant analytical sensitivity to Co(II), Ni(II) and Zn(II) being these their main interferences.eng
dc.description.provenanceSubmitted by (lucia.rodrigues@ufrpe.br) on 2017-02-16T13:10:45Z No. of bitstreams: 1 Romulo Augusto Lins de Campos.pdf: 5930168 bytes, checksum: 7553330ff526456aa81970434c7c3475 (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-02-16T13:10:45Z (GMT). No. of bitstreams: 1 Romulo Augusto Lins de Campos.pdf: 5930168 bytes, checksum: 7553330ff526456aa81970434c7c3475 (MD5) Previous issue date: 2011-03-16eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal Rural de Pernambucopor
dc.publisher.departmentDepartamento de Químicapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFRPEpor
dc.publisher.programPrograma de Pós-Graduação em Químicapor
dc.rightsAcesso Abertopor
dc.subjectEletrodo íon-seletivopor
dc.subjectAgentes sililantespor
dc.subjectEletrodo de pasta de carbonopor
dc.subjectCobrepor
dc.subjectPotenciometriapor
dc.subjectLariat-éter corapor
dc.subjectPotentiometrypor
dc.subjectChemically modified carbon paste electrodespor
dc.subjectLariat-etherpor
dc.subjectCrownpor
dc.subjectCopper (II)por
dc.subjectSilylating agentpor
dc.subjectQuímicapor
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::QUIMICApor
dc.titleEletrodo íon-seletivo de pasta de carbono para determinação de cobre baseado em um novo Lariat-éter coroapor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Romulo Augusto Lins de Campos.pdfDocumento principal5,79 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.