Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/4734
Registro completo de metadados
Campo DCValorIdioma
dc.creatorNOVACK, Nicholas-
dc.creator.Latteshttp://lattes.cnpq.br/0311929047879789por
dc.contributor.advisor1AMORIM, Marleyne José Afonso Accioly Lins-
dc.contributor.advisor-co1COSTA, Fabiano Séllos-
dc.contributor.referee1WISCHRAL, Áurea-
dc.contributor.referee2LEITE, Jacinta Eufrásia Brito-
dc.date.accessioned2016-06-15T12:23:12Z-
dc.date.issued2015-06-15-
dc.identifier.citationNOVACK, Nicholas. Densitometria óssea de gatas castradas e não castradas por tomografia computadorizada quantitativa. 2015. 48 f. Dissertação (Programa de Pós-Graduação em Ciência Animal Tropical) - Universidade Federal Rural de Pernambuco, Recife.por
dc.identifier.urihttp://www.tede2.ufrpe.br:8080/tede2/handle/tede2/4734-
dc.description.resumoA tomografia computadorizada quantitativa (TCQ) é uma técnica de alta sensibilidade, aplicada com precisão no diagnóstico de perda de massa óssea, chamada de densitometria mineral óssea, com grandes vantagens em relação à radiografia simples, porém a falta de valores de normalidade é limitante para a sua aplicação clínica. O presente trabalho teve os seguintes objetivos: estabelecer valores médios da radiodensidade do corpo vertebral da segunda vértebra lombar, através da TCQ, em gatas, aspectos envolvidos na fisiopatologia da osteopenia induzida pela castração; estudar efeitos da depleção dos estrógenos e avaliar as características da radiodensidade das fêmeas da espécie felina de cada grupo experimental, entre as gatas jovens inteiras e as gatas adultas castradas e não castradas acima de 6 anos, em um total de 22 animais. Comparando o grau de normalidade para as gatas adultas jovens e as patologias relacionadas. Estatisticamente comprovou-se uma redução de massa óssea em gatas castrada com mais de 6 anos na segunda vértebra lombar L2.por
dc.description.abstractQuantitative computerized tomography (QCT) is a highly sensitive technique, applied accurately diagnose loss of bone mass, bone mineral densitometry call with great advantages over plain radiography, but the lack of it limiting values for its clinical application. This study had the following objectives: establishing mean values of radiodensity the vertebral body of the second lumbar vertebra through the TCQ in cats, aspects involved in the pathophysiology of osteopenia induced by castration; study effects of depletion of estrogens radiodensity evaluate the characteristics of the female feline species of each experimental group, between the entire young cats and castrated adult cats spayed and not more than 6 years in a total of 22 animals. Comparing the degree of normality for young adult cats, and related. Statistically diseases was proven to be a reduction of bone mass in castrated cats over 6 years second lumbar vertebra L2.eng
dc.description.provenanceSubmitted by Mario BC (mario@bc.ufrpe.br) on 2016-06-15T12:23:12Z No. of bitstreams: 1 Nicholas Novack.pdf: 1065518 bytes, checksum: 960193b642c76d9c5d7a0f4e56572f4f (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-06-15T12:23:12Z (GMT). No. of bitstreams: 1 Nicholas Novack.pdf: 1065518 bytes, checksum: 960193b642c76d9c5d7a0f4e56572f4f (MD5) Previous issue date: 2015-06-15eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal Rural de Pernambucopor
dc.publisher.departmentDepartamento de Morfologia e Fisiologia Animalpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFRPEpor
dc.publisher.programPrograma de Pós-Graduação em Ciência Animal Tropicalpor
dc.rightsAcesso Abertopor
dc.subjectDensitometria ósseapor
dc.subjectTomografia computadorizadapor
dc.subjectFelinopor
dc.subjectRadiodensidadepor
dc.subjectOsteopeniapor
dc.subjectComputerized tomographyeng
dc.subjectBone densitometryeng
dc.subjectFelineeng
dc.subjectRadiodensityeng
dc.subject.cnpqCIENCIAS AGRARIAS::MEDICINA VETERINARIApor
dc.titleDensitometria óssea de gatas castradas e não castradas por tomografia computadorizada quantitativapor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Ciência Animal Tropical

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Nicholas Novack.pdfDocumento principal1,04 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.