Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/4695
Registro completo de metadados
Campo DCValorIdioma
dc.creatorLACERDA, Maria Albeline Silva de-
dc.creator.Latteshttp://lattes.cnpq.br/9579903867511413por
dc.contributor.advisor1WISCHRAL, Aurea-
dc.contributor.referee1COSTA, Fabiano Séllos-
dc.contributor.referee2LEITE, Jacinta Eufrásia Brito-
dc.contributor.referee3AMORIM, Marleyne José Afonso Accioly Lins-
dc.date.accessioned2016-06-13T13:47:43Z-
dc.date.issued2015-02-26-
dc.identifier.citationLACERDA, Maria Albeline Silva de. Ultrassonografia doppler para parâmetros fluxométricos da artéria uterina média de cadelas em estágios fisiológicos e patológico (Piometra). 2015. 45 f. Dissertação (Programa de Pós-Graduação em Ciência Animal Tropical) - Universidade Federal Rural de Pernambuco, Recife.por
dc.identifier.urihttp://www.tede2.ufrpe.br:8080/tede2/handle/tede2/4695-
dc.description.resumoA hemodinâmica das artérias uterinas e o adequado suprimento sanguíneo são importantes para a fisiologia úterina. Assim, objetivou-se estabelecer relações da condição fisiológica (em diferentes fases do ciclo estral) e patológica (piometra) com os parâmetros hemodinâmicos obtidos pela ultrassonografia Doppler colorido e pulsado, em artérias uterinas médias de cadelas. Foram utilizadas 56 cadelas, divididas em fases do ciclo estral: proestro (n=7), estro (n=5), diestro (n=19) e anestro (n=13); e piometra (n=12). Para o exame ultrassonográfico foi utilizado equipamento portátil (M5, Mindray), com sonda convexa (4–8 MHz), para medir automaticamente os índices de pulsatilidade (IP), resistividade (IR), relação sístole/diástole (S/D), velocidades final diastólica (ED), do pico sistólico (PS) e Velocidade Máxima Média do Ciclo (TAMAX), além da frequência cardíaca (HR). O útero foi identificado na avaliação modo-B e, em seguida acionado o modo Doppler, com ângulo de insonação ≤60º. Os resultados fluxométricos não mostraram diferenças entre as fases do ciclo estral. Porém, quando comparados animais em diestro saudável com os apresentando piometra, maiores médias (P<0,05) de IP (8,54±5,92) e IR (1,00±0,11) ocorreram nos saudáveis comparados aos com piometra (IP = 4,49±2,51 e IR = 0,89±0,13). Também foi observada maior média de TAMAX nos com piometra (6,09±15,09 cm/s) comparada aos saudáveis (2,72±1,94 cm/s). Com relação ao PS, foi observada uma tendência (P=0,07) de maior média nos com piometra (29,8±15,35 cm/s) comparados aos saudáveis na fase de diestro (23,08±8,61 cm/s). Os outros parâmetros não mostraram diferença entre os grupos. Conclui-se que as fases do ciclo estral não interferem nos parâmetros hemodinâmicos estudados. Por outro lado, a artéria uterina média apresenta aumento da velocidade de fluxo sanguíneo e diminuição da resistência vascular associada à piometra.por
dc.description.abstractThe hemodynamic of uterine arteries and the adequate blood supply are important to the uterine physiology. The aim of this study was to determine patterns of flowmetry of uterine arteries using Doppler ultrasonography, in physiologic conditions (estrous cycle) and pathologic (pyometra). The animals (n=56) were distributed in heterogenic samples of each phase of estrous cycle (proestrous – n=7, estrous – n=5, dietrous – n= 19 and anestrous – n=13) or pyometra (n=12). All studied animals were submitted to ultrasound mode B exam, and media uterine artery was identified using Doppler tools. The pulsativity (IP), resistivity (IR) and systole/diastole (S/D) indexes and diastolic end (ED), systolic pick (PS), TAMAX, and heart rhythm (HR) were automatically determined by the ultrasound machine. The results showed that there is no significant difference between analyzed parameters and estrous cycle phases. However, comparing healthy animals in diestrus with pyometra, higher averages (P <0.05) of IP (8.54 ± 5.92) and IR (1.00 ± 0.11) was observed in the healthy compared to those with pyometra (PI = 4.49 ± 2.51 and 0.89 ± IR = 0.13). It was also observed higher mean TAMAX in pyometra (6.09 ± 15.09 cm/s) compared to healthy animals (2.72 ± 1.94 cm/s). With respect to the PS, a tendency (P = 0.07) of higher mean value was observed in pyometra (29.8 ± 15.35 cm/s) compared to healthy animals in diestrus phase (23.08 ± 8.61 cm/s). The other parameters showed no difference between groups. It was concluded that the phases of the estrous cycle do not interfere with hemodynamic parameters. Furthermore, the uterine artery blood flow has increased speed and decreased vascular resistance associated with pyometra.eng
dc.description.provenanceSubmitted by Mario BC (mario@bc.ufrpe.br) on 2016-06-13T13:47:43Z No. of bitstreams: 1 Maria Albeline Silva de Lacerda.pdf: 765473 bytes, checksum: c89c99400df21609a6c505748d7ff4d1 (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-06-13T13:47:43Z (GMT). No. of bitstreams: 1 Maria Albeline Silva de Lacerda.pdf: 765473 bytes, checksum: c89c99400df21609a6c505748d7ff4d1 (MD5) Previous issue date: 2015-02-26eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal Rural de Pernambucopor
dc.publisher.departmentDepartamento de Morfologia e Fisiologia Animalpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFRPEpor
dc.publisher.programPrograma de Pós-Graduação em Ciência Animal Tropicalpor
dc.rightsAcesso Abertopor
dc.subjectHemodinâmicapor
dc.subjectParâmetro fluxométricopor
dc.subjectCãopor
dc.subjectReprodução animalpor
dc.subjectUltrassonografiapor
dc.subjectHemodynamiceng
dc.subjectFlowmetry parametereng
dc.subjectDogeng
dc.subjectAnimal reproductioneng
dc.subjectUltrasoundeng
dc.subject.cnpqCIENCIAS AGRARIAS::MEDICINA VETERINARIApor
dc.titleUltrassonografia doppler para parâmetros fluxométricos da artéria uterina média de cadelas em estágios fisiológicos e patológico (Piometra)por
dc.title.alternativeDoppler ultrasound for uterine flowmetry standardization in bitches during physiological stages and pyometraeng
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Ciência Animal Tropical

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Maria Albeline Silva de Lacerda.pdfDocumento principal747,53 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.